What Are Duct Fittings?
A duct fitting is any piece of ductwork that is not a straight length. HVAC duct fittings handle every change in an air system: turning a corner, dropping to a lower level, getting around a beam, splitting off a branch or connecting to a diffuser or piece of equipment. Air duct fittings are shop-fabricated for rectangular duct, while round and spiral duct fittings are usually machine-formed and bought from a supplier.
Duct Fittings Names and What They Do
HVAC duct fittings names vary a little by region and shop, but the main duct fittings names are consistent. A duct elbow turns the air. A duct transition changes the shape, such as rectangular to round at a fan or diffuser. A duct reducer changes the size along a run. A duct wye or tee splits flow into a branch, and a takeoff feeds a smaller branch off a main. The types of duct fittings in the table above cover most of what appears on a commercial HVAC duct fittings schedule.
Rectangular, Spiral and Oval Duct Fittings
Rectangular duct fittings and other sheet metal duct fittings are cut, formed and seamed in the shop from galvanized steel, so their cost follows the weight and the labor to build them. Spiral duct fittings, sold with spiral duct as spiral duct and fittings, are lighter and faster to install. Oval duct fittings fit flat oval duct where ceiling space is tight. Many suppliers sell HVAC duct and fittings together, but on large jobs the fittings are still priced one by one.
Sheet Metal Weight by Gauge
| Gauge | Galvanized Steel Weight (lb per sq ft) |
|---|---|
| 26 | 0.906 |
| 24 | 1.156 |
| 22 | 1.406 |
| 20 | 1.656 |
| 18 | 2.156 |
| 16 | 2.656 |
Fitting weight (lb) = surface area (sq ft) × weight per sq ft for the gauge
The gauge comes from the duct construction table in the specification, set by the duct size and pressure class. Each duct fitting is counted by type and size, then converted to weight so the shop labor and material can be priced.
Duct Fitting Weight Calculator
Put in the size of a rectangular fitting and its gauge weight to get the sheet metal it takes. The starting values are examples.
Area is the perimeter times the centerline length, plus the allowance for seams and laps. 1.156 lb per square foot is 24 gauge galvanized steel.
Common Mistakes When Counting Duct Fittings
- Pricing fittings at the straight duct rate
- Missing the transitions at every fan, coil and diffuser connection
- Using one gauge for every duct size
- Leaving out turning vanes in square elbows
- Missing offsets shown only on sections and details
How The Takeoff AI Handles Ductwork
The Takeoff AI estimates the mechanical and HVAC drawings, schedules and specification, and takes off the ductwork end to end. It measures straight duct, counts every duct fitting, gasket, bolt and weld, works out the weight, and prices the material takeoff (MTO) and labor takeoff (LTO) into a priced bill of materials (BOM) at your own rates. It also builds a 3D model from the 2D drawings, so the duct runs can be checked before pricing.
Every quantity is highlighted on the sheet it came from, and it is trained on more than 1 million drawing sets and runs at 95% accuracy. 113 estimators say The Takeoff AI is the best mechanical estimating software they have used, and it helps them estimate projects in 3 to 4 hours that once took 40 to 50 hours. See it on the mechanical page.